Product specifications

Product Attributes Test method
Weight (Kg) 0.11
Installation torque (Nm) 40 To 45
Filtration 20/18/15 ISO 4406 (maximum filtration admitted)
Orientation Norestrictions
Oil Testing Conditions ISOVG46cSt
Fluid Mineral
Pressure Attributes Test method
Max Pressure (Bar) 350
Flow Attributes Test method
Max Flow (l/min) 40
Viscosities (cSt) 7.4 To 420

Product Description

A solenoid valve operated, 2-way 2-positions, normally closed, piloted poppet type, screw-in cartridge valve. Typically used as ablocking or load holding device for high pressure circuits. When the coil is de-energized, the SVT0.S08 acts as check valve allowingfree flow from 1 to 2, while blocking from 2 to 1. When the coil is energized the poppet lifts and opens both the 2 to 1 and the 1 to 2flow paths. The rigid design using a 1-piece body contributes to minimize the effect of eccentricities in cavity and provides greatreliability. Low pressure drop thanks to optimized flow path.
Product Filter Type
Option Code
Option Code
Override Type
Max Pressure
Bar
Application
SVT0.M18.00.F00 Standard filter (mesh size 280 μm)M18METRIC M18x1,5 with Ø12,9 nose sizeNo override350
SVT0.M18.00.N00 No filterM18METRIC M18x1,5 with Ø12,9 nose sizeNo override350
SVT0.M18.01.F00 Standard filter (mesh size 280 μm)M18METRIC M18x1,5 with Ø12,9 nose sizeScrew350
SVT0.M18.01.N00 No filterM18METRIC M18x1,5 with Ø12,9 nose sizeScrew350
SVT0.M18.02.F00 Standard filter (mesh size 280 μm)M18METRIC M18x1,5 with Ø12,9 nose sizePush and Twist350
SVT0.M18.02.N00 No filterM18METRIC M18x1,5 with Ø12,9 nose sizePush and Twist350
SVT0.M18.06.F00 Standard filter (mesh size 280 μm)M18METRIC M18x1,5 with Ø12,9 nose sizePull and Hold (max. operating pressure: 300 bar)350
SVT0.M18.06.N00 No filterM18METRIC M18x1,5 with Ø12,9 nose sizePull and Hold (max. operating pressure: 300 bar)350
SVT0.M18.09.F00 Standard filter (mesh size 280 μm)M18METRIC M18x1,5 with Ø12,9 nose sizePull and Hold with screw 10-32 UNF (max. operating pressure: 300 bar)350
SVT0.M18.09.N00 No filterM18METRIC M18x1,5 with Ø12,9 nose sizePull and Hold with screw 10-32 UNF (max. operating pressure: 300 bar)350
SVT0.M18.0A.F00 Standard filter (mesh size 280 μm)M18METRIC M18x1,5 with Ø12,9 nose sizePull and Hold with screw M8 (max. operating pressure: 300 bar)350
SVT0.M18.0A.N00 No filterM18METRIC M18x1,5 with Ø12,9 nose sizePull and Hold with screw M8 (max. operating pressure: 300 bar)350
SVT0.M20.00.F00 Standard filter (mesh size 280 μm)M20METRIC M20x1,5 with Ø15 nose sizeNo override350
SVT0.M20.00.N00 No filterM20METRIC M20x1,5 with Ø15 nose sizeNo override350
SVT0.M20.01.F00 Standard filter (mesh size 280 μm)M20METRIC M20x1,5 with Ø15 nose sizeScrew350
SVT0.M20.01.N00 No filterM20METRIC M20x1,5 with Ø15 nose sizeScrew350
SVT0.M20.02.F00 Standard filter (mesh size 280 μm)M20METRIC M20x1,5 with Ø15 nose sizePush and Twist350
SVT0.M20.02.N00 No filterM20METRIC M20x1,5 with Ø15 nose sizePush and Twist350
SVT0.M20.06.F00 Standard filter (mesh size 280 μm)M20METRIC M20x1,5 with Ø15 nose sizePull and Hold (max. operating pressure: 300 bar)350
SVT0.M20.06.N00 No filterM20METRIC M20x1,5 with Ø15 nose sizePull and Hold (max. operating pressure: 300 bar)350
SVT0.M20.09.F00 Standard filter (mesh size 280 μm)M20METRIC M20x1,5 with Ø15 nose sizePull and Hold with screw 10-32 UNF (max. operating pressure: 300 bar)350
SVT0.M20.09.N00 No filterM20METRIC M20x1,5 with Ø15 nose sizePull and Hold with screw 10-32 UNF (max. operating pressure: 300 bar)350
SVT0.M20.0A.F00 Standard filter (mesh size 280 μm)M20METRIC M20x1,5 with Ø15 nose sizePull and Hold with screw M8 (max. operating pressure: 300 bar)350
SVT0.M20.0A.N00 No filterM20METRIC M20x1,5 with Ø15 nose sizePull and Hold with screw M8 (max. operating pressure: 300 bar)350
SVT0.S08.00.F00 Standard filter (mesh size 280 μm)S083/4-16 UNF with Ø12,7 nose sizeNo override350
SVT0.S08.00.N00 No filterS083/4-16 UNF with Ø12,7 nose sizeNo override350
SVT0.S08.01.F00 Standard filter (mesh size 280 μm)S083/4-16 UNF with Ø12,7 nose sizeScrew350
SVT0.S08.01.N00 No filterS083/4-16 UNF with Ø12,7 nose sizeScrew350
SVT0.S08.02.F00 Standard filter (mesh size 280 μm)S083/4-16 UNF with Ø12,7 nose sizePush and Twist350
SVT0.S08.02.N00 No filterS083/4-16 UNF with Ø12,7 nose sizePush and Twist350
SVT0.S08.06.F00 Standard filter (mesh size 280 μm)S083/4-16 UNF with Ø12,7 nose sizePull and Hold (max. operating pressure: 300 bar)350
SVT0.S08.06.N00 No filterS083/4-16 UNF with Ø12,7 nose sizePull and Hold (max. operating pressure: 300 bar)350
SVT0.S08.09.F00 Standard filter (mesh size 280 μm)S083/4-16 UNF with Ø12,7 nose sizePull and Hold with screw 10-32 UNF (max. operating pressure: 300 bar)350
SVT0.S08.09.N00 No filterS083/4-16 UNF with Ø12,7 nose sizePull and Hold with screw 10-32 UNF (max. operating pressure: 300 bar)350
SVT0.S08.0A.F00 Standard filter (mesh size 280 μm)S083/4-16 UNF with Ø12,7 nose sizePull and Hold with screw M8 (max. operating pressure: 300 bar)350
SVT0.S08.0A.N00 No filterS083/4-16 UNF with Ø12,7 nose sizePull and Hold with screw M8 (max. operating pressure: 300 bar)350
SVT0.S09.00.F00 Standard filter (mesh size 280 μm)S093/4-16 UNF with Ø15,86 nose sizeNo override350
SVT0.S09.00.N00 No filterS093/4-16 UNF with Ø15,86 nose sizeNo override350
SVT0.S09.01.F00 Standard filter (mesh size 280 μm)S093/4-16 UNF with Ø15,86 nose sizeScrew350
SVT0.S09.01.N00 No filterS093/4-16 UNF with Ø15,86 nose sizeScrew350
SVT0.S09.02.F00 Standard filter (mesh size 280 μm)S093/4-16 UNF with Ø15,86 nose sizePush and Twist350
SVT0.S09.02.N00 No filterS093/4-16 UNF with Ø15,86 nose sizePush and Twist350
SVT0.S09.06.F00 Standard filter (mesh size 280 μm)S093/4-16 UNF with Ø15,86 nose sizePull and Hold (max. operating pressure: 300 bar)350
SVT0.S09.06.N00 No filterS093/4-16 UNF with Ø15,86 nose sizePull and Hold (max. operating pressure: 300 bar)350
SVT0.S09.09.F00 Standard filter (mesh size 280 μm)S093/4-16 UNF with Ø15,86 nose sizePull and Hold with screw 10-32 UNF (max. operating pressure: 300 bar)350
SVT0.S09.09.N00 No filterS093/4-16 UNF with Ø15,86 nose sizePull and Hold with screw 10-32 UNF (max. operating pressure: 300 bar)350
SVT0.S09.0A.F00 Standard filter (mesh size 280 μm)S093/4-16 UNF with Ø15,86 nose sizePull and Hold with screw M8 (max. operating pressure: 300 bar)350
SVT0.S09.0A.N00 No filterS093/4-16 UNF with Ø15,86 nose sizePull and Hold with screw M8 (max. operating pressure: 300 bar)350