The outriggers of a spider crane are locked by valves that block the outrigger cylinders once they are set.
Before a spider crane lifts, it sets up on its outriggers. This lifts the crane slightly off its tracks and gives it a wide, stable base. The outrigger cylinders then have to stay exactly in position, regardless of the load and the direction in which the boom is slewing.
For that reason, the outrigger circuits use valves that seal without leakage, such as pilot operated check valves. A standard spool valve always has some internal leakage, which over time would let an outrigger creep in. A leak-tight valve prevents that.
This keeps the crane stable throughout the lift, also when the work takes longer.