A spider crane holds its load with load holding valves on the cylinders, which lock the oil in so the boom and the load stay where they are.
A load holding valve, also called an overcenter valve, is mounted directly on the cylinder. When the operator stops a movement, the valve closes and the oil cannot leave the cylinder. The boom stays in position without the pump having to keep running.
Because the valve sits on the cylinder itself, it also holds the load if a hose or connection fails. That is an important safety function for a crane that often works with people nearby.
Load holding valves also control the lowering movement. When the boom comes down, the valve makes sure the load cannot run ahead of the oil supply, so the movement stays smooth and controlled.